| TYPUS | M22W-240-0007 |
| Tensio Aestimata VR | 240V |
| Tensio Impulsiva VS1 | 248V |
| Capacitas Aestimata CDuo | 7.5F. |
| Tolerantia CapacitatisTres | -0% / +20% |
| ESR2 | ≤67mΩ |
| Currentis Fugae ILquattuor | <3 mA |
| Ratio auto-exonerationis5 | <20% |
| Specificatio cellulae | 3V 600F |
| Capacitas maxima repositionis uniuscellulaE.9 | 0.75Wh |
| Configuratio moduli | 1 P. 80S |
| Currens Constans IMCC(ΔT = 15°C)6 | 39 A |
| Maxima Currens IMaximus7 | 0.6kA |
| Brevis Currens IS8 | 3.6kA |
| Energia Reposita E9 | 60Qu? |
| Densitas Energiae Ed 10 | 3Wh/kg |
| Densitas Potentiae Utilis Pd11 | 5.2kW/kg |
| Impedentia Potentiae Congruens PdMax12 | 10.8kW/kg |
| Classis tensionis sustinendae insulationis | 4800V CC/minutum |
| TYPE | M22W-240-0007 |
| Temperatura Operativa | -40 ~ 65°C |
| Temperatura Reponendi13 | -40 ~ 70°C |
| Resistentia Thermalis RTh14 | 0.15K/W |
| Capacitas Thermalis Cth15 | 24000J/K |
| TYPUS | M22W-240-0007 |
| Vita DC ad Altam Temperaturam16 | Horae mille quingentarum |
| Vita DC apud RT17 | decem anni |
| Cyclus Vitae18 | Mille cycli |
| Tempus Vitae19 | quattuor anni |
| TYPUS | M22W-240-0007 |
| Salus | DL/T 2080-2020 |
| Vibratio | DL/T 2080-2020 |
| Impetus | NA |
| Gradus tutelae | NA |
| TYPUS | M22W-240-0007 |
| Sensor temperaturae internae | NTC RTD (10K) |
| Interfacies temperaturae | simulatio |
| Detectio tensionis pilae | Signum alarmis moduli tensionis excessivae, signum nodi passivi, tensio alarmis moduli: Dc141.6 ~ 146.4v |
| Administratio tensionis pilae | Comparatoris aequalisationis passivae administratio |
| TYPUS | M22W-240-0007 |
| Massa M | ≤20chiliogrammata |
| Terminales (ducta)20 | M5&c.,torques 6-8Nm |
| Terminale signalis | Quadruplacus Terminalis, egressus copulationis opticae 2pin, egressus temperaturae 2pin |
| Modus refrigerationis | Refrigeratio naturalis |
| Dimensiones21Longitudo × Latitudo × Altitudo | 435×581.5×82.5mm |
| Situs foraminis moduli adfigendi | Installatio generis scrinii |